CD3000S 2PH


Technical Specification
  • Voltage power supply: 24V min, 480V Max, 600V on request
  • Input Signal: SSR (OFF state <1Vdc ON = 4÷30 Vdc) is standard up to 90A included. Analog input 4÷20mA and 0÷10V is available from 35A (included) to 90A (included)
  • Firing: Zero crossing ZC; Burst Firing 4/8/16 with 4÷20mA or 0÷10V with 12÷24V aux. power supply.
  • Fan Voltage: 230V ± 15% standard f(110V on request opt., if current ≥75A).
  • Heater Break Alarm: Discrimination better than 20%. * Circuit microprocessor based to diagnose partial or total load failure and short circuit on Thyristor. * Latching alarm plus reset. * Relay output 1A at 230V. * Automatic calibration of one or more unit at the same time using a dedicated digital input or using for each unit the calibration button.
  • Approvals: Comply with EMC; cULus available as an option on basic units.
  • Mounting: Din rail mounting up to 90A included.
  • Operating Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve)

General Details

CD3000S 2PH

From 10A to 90A

General description

CD3000S 2PH two leg switching three wire load star or delta resistive loads or infrared lamps up to 90A.

  • Fully isolated from power.
  • Zero crossing firing available with logic input signal (SSR)
  • Constant current drain with SSR input
  • Analog input 4÷20mA or 0÷10V with burst firing 4, 8 or 16 cycle at 50% power demand, is available as an option from 35A to 90A.
  • Heater break alarm (HB) to diagnostic partial or total load failure and short circuit on thyristor, is available as an option from 35A to 90A
  • Side by side mounting.
  • Special design for heatsink with high dissipation
  • Comply with EMC specification CE and cUL

Downloag Catalog



Heater Break Alarm (HB)


  • Microprocessor based circuit
  • Self learning of current set, via external command or push button on front unit.
  • Load break diagnostic with alarm latch.
  • Thyristor short circuit diagnostic.
  • Alarm reset function and possibility to auto reset the alarm if the normal working condition is restored.
  • Alarm output with free voltage contact.
  • Available from 35A÷90A incl.
  • Full insulation between SSR output coming from controller/multi loop and power supply, no common zero in our unit.
  • Easy and fast substitution/calibrate of the unit (also not expert people can do it easy).

Burst Firing (BF)


  • This firing performed in digital mode in our unit gives a lot advantage because switch thyristor faster than normal ZC and at the same time without EMC interferences.
  • Analog input is necessary for BF and can be decided how many complete cycles we want at 50% of power demand.
  • On CD3000S this value can be 4, 8, 16.
  • To have a better resolution use REVEX series, where the BF value can be implemented from 1 to
    255 complete cycles doing the firing less or more fast.
Code & Size

CD3000S 2PH – Order Code


CD3000S 2PH – Size & Dimensions

Documentation

CD3000S 2PH – Documentation


Manuals

NameSize
ENG L M CD CD3000S-2PH 10-100A

Manual CD3000S 2PH from 10A to 110A (English Version)

0.3 MiB
ENG L M CD CD3000S-2PH 45-100A SSR-HB

Manual CD3000S 2PH from 45A to 100A with Heater Break Alarm (English Version)

0.4 MiB
ENG L M CD CD3000S-2PH 45-100A Analog-Input

Manual CD3000S 2PH from 45A to 100A with Analog Input (English Version)

0.4 MiB
ENG L M CD CD3000S-2PH 125-700A

Manual CD3000S 2PH from 125A to 700A (English Version)

0.8 MiB
FRA L M CD CD3000S-2PH 10-100A

Manuel CD3000S 2PH de 10A à 110A (Version Française)

0.3 MiB
FRA L M CD CD3000S-2PH 125-700A

Manuel CD3000S 2PH de 125A à 700A (Version Française)

1.2 MiB
GER L M CD CD3000S-2PH 35-100A Analog-Input

Handbuch CD3000S 2PH Thyristorsteller mit Analogeingang von 35A ÷ 100A

0.5 MiB
GER L M CD CD3000S-2PH 10-100A

Handbuch CD3000S 2PH Thyristorsteller von 10A ÷ 100A

0.3 MiB
ITA L M CD CD3000S-2PH 10-100A

Manuale CD3000S 2PH da 10A a 110A (Versione Italiano)

0.3 MiB
ITA L M CD CD3000S-2PH 45-100A Analog-Input

Manuale CD3000S 2PH da 45A a 100A Ingresso Analogico (Versione Italiano)

0.4 MiB
ITA L M CD CD3000S-2PH 45-100A SSR-HB

Manuale CD3000S 2PH da 45A a 100A versione Allarme Heater Break (Versione Italiano)

0.4 MiB
ITA L M CD CD3000S-2PH 125-700A

Manuale CD3000S 2PH da 125A a 700A (Versione Italiano)

0.8 MiB

Catalog


Copyright © 2010 Cd Automation S.r.l. - Via P.Picasso 34/36, Legnano, MI - Tel: +39 0331 577479 - Fax: +39 0331 579479 - - PIVA:IT08925720156 - Tribunale di Milano REA:1255303 - Capitale sociale:€ 26.000,00 - All Rights Reserved.
ASK FOR INFORMATION AND QUOTATION
| Informativa Privacy | Informativa Cookie |
Diritti Interessati | Impostazioni Cookie |