- Home
- Selector
- SCR Power Controller
- CUSTOM 1PH 1700-2700A
CUSTOM 1PH 1700-2700A, Vmax=480V|600V|690V, Size=s34
CUSTOM 1PH is a product that can be customized
* These simple units can be connected with REVO PC to manage multizone system this minimize your energy cost by controlling synchronization and power limit on each zone
* All circuit board, fuses and Thyristor can be inspected just opening front doar
* Input signal: SSR, Analog as an option
* Zero Crossing, Burst Firing available at 4, 8 or 16 Cycles at 50% Power demand
* Electronic circuit fully isolated from power with constant current drain on input.
* Heater Break alarm option to diagnose partial or total load failure and Thyristor Short circuit
* Internal fixed fuses are standard
* Current transformer integrated
* Special design for Heat sink with very high dissipation value
* Comply with EMC
* Panel Mounting
* IP20 Protection available as option
- Description
- Additional information
Description
Related Products
CD3000M 2PH 45A
CD3000M 2PH 45A, Vmax=480V|600V, Size=s7c
CD3000M-2PH is a digital and universal Thyristor unit fully configurable via serial communication port.
* RS485 Modbus protocol comm is included as standard
* Two phase Thyristors to control 3 phase Star or Delta resistive loads up to 700A
* Microprocessor based electronic circuit fully isolated from power
* Universal Input signal with automatic zero/span calibration
* Firing, customer configurable via serial port Zero Crossing, Burst Firing
* Heater Break circuit microprocessor based to diagnose load failure and short circuit on Thyristors is available as an option
* Possibility to read and write the parameters via external key pad: CD-KP
* External Fuse holder and fuses up to 100A, Internal Fuses from 125A to 700A.
* Comply with EMC and cUL
* IP20 protection
CD3000M 1PH 110A
CD3000M 1PH 110A, Vmax=480V|600V, Size=s8c
CD3000M is a digital and universal Thyristor unit, configurable via serial communication port
* RS485 comm Modbus protocol is included as standard
* Single phase Thyristor unit up to 700A
* Suitable to drive resistive loads with Zero Crossing firing and one phase transformer with Delayed Triggering Microprocessor based electronic circuit fully isolated from power
* Universal Input signal
* Universal Firing, customer configurable via serial port Zero Crossing, Single Cycle, Burst Firing, Delayed Triggering and Phase Angle
* Soft Start can be used with Burst Firing Heater Break circuit microprocessor based to diagnose load failure and short circuit on Thyristors is an option.
* Possibility to read and write the parameters via an external Key pad: cd-kp
* External fuseholder and fuses up to 110A, internal fuses over 110A
* Comply with EMC and cUL
* IP20 Protection
CD3000M 3PH 15A
CD3000M 3PH 15A, Vmax=480V|600V, Size=s2c
CD3000M-3PH is a digital and universal Thyristor unit fully configurable via serial communication port.
* Rs485 Modbus protocol comm is included as standard
* Three phase Thyristors to control Star 3/4 Wires or Delta 3/6 Wires resistive loads up to 500A
* Microprocessor based electronic circuit fully isolated from power
* Universal Input signal with automatic zero/span calibration
* Firing, customer configurable via serial port Zero Crossing, Burst Firing
* Heater Break circuit microprocessor based to diagnose load failure and short circuit on Thyristors is available as an option.
* Possibility to read and write the parameters via external key pad: CD-KP
* External Fuses + Fuse holder up to 90A, Internal Fuses from 125A to 500A.
* Comply with EMC and cUL
* IP20 protection
CD3000M 3PH 125-150A
CD3000M 3PH 125-150A, Vmax=480V|600V, Size=s11
CD3000M-3PH is a digital and universal Thyristor unit fully configurable via serial communication port.
* Rs485 Modbus protocol comm is included as standard
* Three phase Thyristors to control Star 3/4 Wires or Delta 3/6 Wires resistive loads up to 500A
* Microprocessor based electronic circuit fully isolated from power
* Universal Input signal with automatic zero/span calibration
* Firing, customer configurable via serial port Zero Crossing, Burst Firing
* Heater Break circuit microprocessor based to diagnose load failure and short circuit on Thyristors is available as an option.
* Possibility to read and write the parameters via external key pad: CD-KP
* External Fuses + Fuse holder up to 90A, Internal Fuses from 125A to 500A.
* Comply with EMC and cUL
* IP20 protection
CD3000M 1PH 60-90A
CD3000M 1PH 60-90A, Vmax=480V|600V, Size=s7c
CD3000M is a digital and universal Thyristor unit, configurable via serial communication port
* RS485 comm Modbus protocol is included as standard
* Single phase Thyristor unit up to 700A
* Suitable to drive resistive loads with Zero Crossing firing and one phase transformer with Delayed Triggering Microprocessor based electronic circuit fully isolated from power
* Universal Input signal
* Universal Firing, customer configurable via serial port Zero Crossing, Single Cycle, Burst Firing, Delayed Triggering and Phase Angle
* Soft Start can be used with Burst Firing Heater Break circuit microprocessor based to diagnose load failure and short circuit on Thyristors is an option.
* Possibility to read and write the parameters via an external Key pad: cd-kp
* External fuseholder and fuses up to 110A, internal fuses over 110A
* Comply with EMC and cUL
* IP20 Protection
CD3000M 1PH 300-700A
CD3000M 1PH 300-700A, Vmax=480V|600V, Size=s12
CD3000M is a digital and universal Thyristor unit, configurable via serial communication port
* RS485 comm Modbus protocol is included as standard
* Single phase Thyristor unit up to 700A
* Suitable to drive resistive loads with Zero Crossing firing and one phase transformer with Delayed Triggering Microprocessor based electronic circuit fully isolated from power
* Universal Input signal
* Universal Firing, customer configurable via serial port Zero Crossing, Single Cycle, Burst Firing, Delayed Triggering and Phase Angle
* Soft Start can be used with Burst Firing Heater Break circuit microprocessor based to diagnose load failure and short circuit on Thyristors is an option.
* Possibility to read and write the parameters via an external Key pad: cd-kp
* External fuseholder and fuses up to 110A, internal fuses over 110A
* Comply with EMC and cUL
* IP20 Protection