REVEX 1PH – The Power Controller On Demand

REVEX 1PH


Technical Specification
  • Load type: Normal Resistance, Infrared Short, Medium and Long, Transformer Primary, Cold resistance and SiC elements
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
  • Firing mode: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering, Phase Angle with or without Soft Start
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • Communication: RS485 port. RTU Modbus® Protocol
  • USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • Approvals: Comply with EMC
  • Dual Current Limit: For peak and RMS value
Option
  • All options are shown below with the relevant model code
  • HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circuit
blank

REVEX 2PH – The Power Controller On Demand

REVEX 2PH


Technical Specification
  • Load type: Normal Resistance, Infrared Short, Medium and Long waveform
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
  • Firing mode: Burst Firing, Zero Crossing
  • Control Mode: Voltage, Current and Power or V2 and I2
  • Communication: RS485 port. RTU Modbus® Protocol
  • USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • Approvals: Comply with EMC
  • Dual Current Limit: For peak and RMS value
Option
  • All options are shown below with the relevant model code
  • HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circuit
blank

REVO C 1PH – Revo Connect Universal SCR Power Controller Single Phase

Schema di collegamento del REVO C monofase

REVO C 1PH


  • Phases: 1
  • Current Range from 30 to 2100A.
  • Voltage Range 480V, 600V and 690V.
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Firing mode: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering, Phase Angle with or without Soft Start
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 kA: Short Circuit Current Rating (SCCR) up to 600V
  • Approvals CE+EMC; cUL from 30A to 700A, UL from 800A to 2100A

REVEX 3PH – The Power Controller On Demand

REVEX 3PH


Technical Specification
  • Load type: Normal Resistance, Infrared Short, Medium and Long Waveform
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
  • Firing mode: Burst Firing, Zero Crossing
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • Communication: RS485 port. RTU Modbus® Protocol
  • USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • Approvals: Comply with EMC
  • Dual Current Limit: For peak and RMS value
Option
  • All options are shown below with the relevant model code
  • HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circuit
blank

REVO C 2PH – Revo Connect Universal SCR Power Controller Two Phases

Schema di collegamento del REVO C bifase

REVO C 2PH


  • Phases: 2
  • Current Range from 30 to 2100A.
  • Voltage Range 480V, 600V and 690V.
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Load type: Normal Resistance, Infrared Short, Medium and Long, Transformar Primary using Delayed Triggering
  • Firing mode: Burst Firing, Zero Crossing.
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 kA: Short Circuit Current Rating (SCCR) up to 600V
  • Approvals CE+EMC; cUL from 30A to 700A, UL from 800A to 2100A

REVO C 3PH – Revo Connect Universal SCR Power Controller Three Phases

Schema di collegamento del REVO C trifase

REVO C 3PH


  • Phases: 3
  • Current Range from 30 to 2100A.
  • Voltage Range 480V, 600V and 690V.
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Firing mode: Burst Firing, Delayed Triggering and Phase Angle with or without Soft Start
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 kA: Short Circuit Current Rating (SCCR) up to 600V
  • Approvals CE+EMC; cUL from 30A to 500A, UL from 600A to 2100A