Thyristor Power Controller three phase two legs, suitable for Normal Resistance, Medium lamp Long Wave IR, and Silicon Carbide load types

CD3000S 2PH – From 10A to 90A

CD3000S 2PH


Technical Specification
  • Voltage power supply: 24V min, 480V Max, 600V on request
  • Input Signal: SSR (OFF state <1Vdc ON = 4÷30 Vdc) is standard up to 90A included. Analog input 4÷20mA and 0÷10V is available from 35A (included) to 90A (included)
  • Firing: Zero crossing ZC; Burst Firing 4/8/16 with 4÷20mA or 0÷10V with 12÷24V aux. power supply.
  • Fan Voltage: 230V ± 15% standard f(110V on request opt., if current ≥75A).
  • Heater Break Alarm: Discrimination better than 20%. * Circuit microprocessor based to diagnose partial or total load failure and short circuit on Thyristor. * Latching alarm plus reset. * Relay output 1A at 230V. * Automatic calibration of one or more unit at the same time using a dedicated digital input or using for each unit the calibration button.
  • Approvals: Comply with EMC; cULus available as an option on basic units.
  • Mounting: Din rail mounting up to 90A included.
  • Operating Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve)

REVEX 2PH – The Power Controller On Demand

REVEX 2PH


Technical Specification
  • Load type: Normal Resistance, Infrared Short, Medium and Long waveform
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
  • Firing mode: Burst Firing, Zero Crossing
  • Control Mode: Voltage, Current and Power or V2 and I2
  • Communication: RS485 port. RTU Modbus® Protocol
  • USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • Approvals: Comply with EMC
  • Dual Current Limit: For peak and RMS value
Option
  • All options are shown below with the relevant model code
  • HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circuit

REVO C 2PH – Revo Connect Universal SCR Power Controller Two Phases

Schema di collegamento del REVO C bifase

REVO C 2PH


  • Phases: 2
  • Current Range from 30 to 2100A.
  • Range di tensione 480V, 600V & 690V.
  • Inputs: 4:20mA , 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Load type: Normal Resistance, Infrared Short, Medium and Long, Transformar Primary using Delayed Triggering
  • Firing mode: Burst Firing , Zero Crossing.
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 KA: Short Circuit Current rating (SCCR) up to 600V
  • cUL / UL and CE + EMC approved

REVO S 2PH Thyristor Power Controller

REVO S 2PH


  • From 30 up to 700A
  • Voltage range 480V, 600V and 690V
  • Load type: Resistance, IR Lamp long and medium waveform
  • Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
  • Firing mode: Zero Crossing, Burst Firing available with analogue input only

REVO TC 2PH Temperature and Power Controller PID

REVO TC 2PH


  • Suitable for Normal Resistance
  • Three Phase 2PH (2-Leg) From 30A to 210A
  • Max. voltage 480V, 600Vac
  • Load type: Resistance
  • Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
  • Heather Break alarm options
  • Firing mode: Zero Crossing

Revo PN – Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems

REVO PN


  • Modules of 12 or 24 zones already divided into three phases or one phase from 4 to 24 zones
  • Logic input SSR 7 ÷ 30Vdc 9mA Max (ON ≥7Vdc OFF < 6Vdc)
  • L1 - L2 - L3 Power Input 370 - 480V
  • Nominal current in continuous service Max 25A for each load
  • Max peak current (10ms) 700A
  • Nominal Voltage range Ue 24 - 600V
  • Isolation Voltage Ui 2500Vac
  • N° 8 out SSR + CT input Option T digit 16 on ordring code

Multidrive 2PH Thyristor Power Controller

MULTIDRIVE 2PH


  • From 45 up to 2700A
  • Max. voltage 480V or 600V & 690V AC as an option
  • Load type: Inductive Load, Transformer and Pure Resistance Element.
  • Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
  • Firing mode: Burst Firing, Delay Triggering + Burst Firing (DT)
  • N°4 Retransmission are available plus IO

Custom 2PH 1100A to 2700A SCR Power Controller

  • Two phase thyristor: Unit from 1100 to 2700A
  • Suitable to drive: 3 phase loads at 480-600-690V with 2 phase controlled
  • Inputs: SSR Standard, 0:10V, 4:20mA selectable
  • Firing mode: Zero Crossing and Burst Firing available with analog input and configurable from 1 to 255 cycles ON at 50% power demand