New REVO C

The Thyristor Evolution

REVO Connect is a high reliability universal power regulator that has an advanced microprocessor that makes it universal and completely configurable via software. Particular attention was paid to the Connectivity with the most popular Field Buses and to the management of the unit via Wi-Fi (optional) with CD Automation APP to be installed on your Smartphone.

REVO C 1PH – Revo Connect Universal SCR Power Controller Single Phase

Schema di collegamento del REVO C monofase

REVO C 1PH


  • Phases: 1
  • Current Range form 30 to 2100A.
  • Voltage Range 480V, 600V and 690V .
  • Inputs: 4:20mA , 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Firing mode: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering, Phase Angle with or without Soft Start
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 KA: Short Circuit Current rating (SCCR) up to 600V
  • cUL / UL and CE + EMC approved

REVO C 2PH – Revo Connect Universal SCR Power Controller Two Phases

Schema di collegamento del REVO C bifase

REVO C 2PH


  • Phases: 2
  • Current Range from 30 to 2100A.
  • Range di tensione 480V, 600V & 690V.
  • Inputs: 4:20mA , 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Load type: Normal Resistance, Infrared Short, Medium and Long, Transformar Primary using Delayed Triggering
  • Firing mode: Burst Firing , Zero Crossing.
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 KA: Short Circuit Current rating (SCCR) up to 600V
  • cUL / UL and CE + EMC approved

REVO C 3PH – Revo Connect Universal SCR Power Controller Three Phases

Schema di collegamento del REVO C trifase

REVO C 3PH


  • Phases: 3
  • Current Range form 30 to 2100A.
  • Voltage Range 480V, 600V and 690V.
  • Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
  • Firing mode: Burst Firing, Delayed Triggering and Phase Angle with or without Soft Start
  • Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
  • USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
  • 100 KA: Short Circuit Current rating (SCCR) up to 600V
  • cUL / UL and CE + EMC approved

Copyright © 2010 Cd Automation S.r.l. - Via P.Picasso 34/36, Legnano, MI - Tel: +39 0331 577479 - Fax: +39 0331 579479 - - PIVA:IT08925720156 - Tribunale di Milano REA:1255303 - Capitale sociale:€ 26.000,00 - All Rights Reserved.
ASK FOR INFORMATION AND QUOTATION
| Informativa Privacy | Informativa Cookie |
Diritti Interessati | Impostazioni Cookie |