REVO TC 1PH
- Suitable for Normal Resistance load types
- From 30A to 210A
- Max. voltage 480V, 600Vac
- Load type: Resistance
- Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
- Heather Break alarm options
- Firing mode: Zero Crossing
- General Details
- Manuals
- Datasheet
- SW
- Size
REVO TC 1PH
Temperature and Power Controller
- Suitable for Normal Resistance load types
- Current range – 30A, 35A, 40A, 60A, 90A, 120A, 150A, 180A, 210A
- Supply voltage up to 480V, 600Vac
- Microprocessor based electronic circuit fully isolated from the power
- Thyristor Firing types include Zero Crossing Firing
- Controller input signals from Thermocouple, PT100 (3 wire RTD), 4-20mA and 0-10V DC Linear
- Up to 4 configurable Controller outputs (Relay, SSR and 4-20mA)
- Heater Break (HB) alarm to diagnose partial or total load failure with automatic setting, relay alarm output and front LED indication. Available as an option
- Internal quick-blow fuses as standard
- RS485 comms (Modbus Protocol) as standard
- Internal Current Transformer included as standard
- Special design Heatsink with high dissipation value
- IP20 protection
- Complies with CE specification
REVO TC 1PH is a Compact Solution that Integrate Temperature and Power Controller in One Unit:
- Single Loop PID Temperature controller
- 1PH Thyristor Power Controle units
- Current Transformers
- Fuse-Holder
The final result is a cost saving in terms of space and cabling.
Name | Size |
---|
Eng-RevoTC 30-40 1ph Part1 User's Manual Temperature Controller Revo TC 30-40A 1ph - Part 1 | 2.3 MiB![]() |
Eng-RevoTC 30-40 1ph Part2 User's Manual Temperature Controller Revo TC 1ph 30-40A - Parte 2 | 0.7 MiB![]() |
Ita-RevoTC 30-40 1ph Part1 Manuale utente Termoregolatore Revo TC - Parte 1 | 1.9 MiB![]() |
Ita-RevoTC 30-40 1ph Part2 Manuale utente Termoregolatore Revo TC 30-40A - Parte 2 | 0.8 MiB![]() |
Name | Size |
---|
REVO TC 1PH Datasheet REVO TC 1PH | 0.5 MiB![]() |
Revo-TC-Configurator REVO TC configuration software | 4.5 MiB![]() |
Driver-USB-for-programming-cable CCA Cable for unit configuration need a driver to be used on Windows PC. This is the executable version to install automatically the driver into the PC system. | 2.0 MiB![]() |
Driver-USB-for-programming-cable CCA Cable for unit configuration need a driver to be used on Windows PC. This is the zipped version of ini file. | 1.3 MiB![]() |
Files di configurazione Modbus:
Name | Size |
---|
PROFINET-Serial Communication RTC REVO TC PROFINET - Serial Communication Manual (TU-RS485-PNT0TCMxx) | 1.1 MiB![]() |
TU-RS485-Revo TC-zone Configurations Zone Configuration Files for TU-RS485-xxxxTCMxx | 19 KiB![]() |
GSD and GSDM files for Profibus and Profinet:
PROFIBUS-GSD-Files File GSD (General Station Description File) - Field bus PROFIBUS configuration file / File di configurazione del bus di campo PROFIBUS | 11 KiB![]() |
PROFINET-GSDML-Files File GSDML (General Station Description File) - Field bus PROFINET configuration file / File di configurazione del bus di campo PROFINET | 85 KiB![]() |