• From 30 up to 700A
  • Max. voltage 480V or 600V AC as option
  • Load type: Resistance, IR Lamp long and medium waveform
  • Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
  • Firing mode: Zero Crossing, Burst Firing available with analogue input only



General Details

REVO S 1PH Thyristor Power Controller

  • REVO S 1PH Thyristor Power Controller is suitable for resistive and medium or long wave infrared loads
  • Current range – 30A, 35A, 40A, 60A, 90A, 120A, 150A, 180A, 210A, 280A, 400A, 500A, 600A, 700A
  • Supply voltage up to 480V or 600V AC as option
  • Fully isolated from the power
  • Zero crossing firing mode (ZC) or Burst Firing (4, 8 or 16 cycles selectable)
  • Logic input signal 4 to 30V DC typical (SSR) plus 4-20mA or 0-10V DC Linear input as an option
  • Constant current drain, independent of supply voltage with SSR input
  • Heater Break (HB) alarm to diagnose partial or total load failure with automatic setting, relay alarm output and front LED indication. Available as an option
  • Side by side mounting
  • Special design Heatsink with high dissipation value
  • IP20 protection
  • Complies with CE and cUL (pending)
  • Can be used in conjunction with REVO-PC to provide multi-zone control
Manuals

en

English

NameSizeDate
ENG_L_M__CD REVO S 30A 40A 1PH

Manual REVO S 1PH from 30A to 40A (English Version)

1.0 MiB 4 June 2014
ENG_L_M__CD REVO S 1PH 280A to 700A

Manual REVO S 1PH from 280A to 700A (English Version)

2.6 MiB 4 June 2014
ENG_L_M__CD REVO S 1PH 60A to 210A

Manual REVO S 1PH from 60A to 210A (English Version)

1.6 MiB 4 June 2014
ENG_L_M__CD REVO S 30A 40A 1PH + Fuse and Fuse holder

Manual REVO S 1PH from 30A to 40A - unit with internal fuse extrarapid (English Version)

1.1 MiB 4 June 2014

it

Italiano

NameSizeDate
ITA_L_M__CD REVO S 1PH 280A to 700A

Manuale REVO S 1PH da 280A a 700A (Versione Italiano)

2.6 MiB 4 June 2014
ITA_L_M__CD REVO S 1PH 30A 40A + Fuse and Fuse holder

Manuale REVO S 1PH da 30A a 40A - unità con fusibile interno (Versione Italiano)

1.1 MiB 4 June 2014
ITA_L_M__CD REVO S 1PH 30A to 40A

Manuale REVO S 1PH da 30A a 40A (Versione Italiano)

1.0 MiB 4 June 2014
ITA_L_M__CD REVO S 1PH 60A to 210A

Manuale REVO S 1PH da 6A a 210A (Versione Italiano)

1.7 MiB 4 June 2014

de

Deutsch

NameSizeDate
GER_L_M__CD REVO S 1PH 280A to 700A

Manuelle REVO S 1PH von 280A bis 700A (Deutsch Version)

1.8 MiB 4 June 2014
GER_L_M__CD REVO S 1PH 30A 40A

Manuelle REVO S 1PH von 30A bis 40A (Deutsch Version)

712.9 KiB 4 June 2014
GER_L_M__CD REVO S 1PH 30A to 40A + Fuse and Fuse holder

Manuelle REVO S 1PH von 30A bis 40A - Geräte mit internen Sicherung (Deutsch Version)

1.1 MiB 4 June 2014
GER_L_M__CD REVO S 1PH 60A 210A

Manuelle REVO S 1PH von 60A bis 210A (Deutsch Version)

1.5 MiB 4 June 2014

 

Datasheet
NameSizeDate
ENG_REVO S 1PH 280A To 700A

Datasheet REVO S 1PH Thyristor Power Controller from 280A to 700A (English Version)

405.7 KiB 4 June 2014
ENG_REVO S 1PH 30A To 40A

Datasheet REVO S 1PH Thyristor Power Controller from 30A to 40A (English Version)

376.2 KiB 4 June 2014
ENG_REVO S 1PH 60A To 210A

Datasheet REVO S 1PH Thyristor Power Controller from 60A to 210A (English Version)

394.2 KiB 4 June 2014

 

Size & Dimensions