REVO TH


Technical Specifications
  • REVEX PA
    SCR power controller with advanced functions
  • Type of load: Normal resistors, short, medium and long wave infrared lamps.
  • Inputs: 4: 20mA, 0: 10V, SSR and Modbus® as standard.
  • Firing: Burst Firing, Phase Angle, Delayed Triggering, Zero Crossing.
  • Type of control: Voltage, Current, Power or V2 and I2 with Transfer to VxI.
  • Communication: RS485 port Modbus® RTU protocol.
  • USB: Integrated port for configuration in safe mode without the need for load and auxiliary voltage). The unit is powered via USB.
  • Approvals: EMC compliant.

General Details

REVEX PA

SCR power controller with advanced functions

 

The power controller REVEX PA is the latest born in the REVEX family.
The REVEX are positioned between the two families REVO S and REVO C in terms of price and performance. The main characteristic is that they can be configured according to your needs by eliminating of all options that you do not want to use, in order to reduce the purchase price. It is an extremely flexible and performing unit.

The REVEX PA is a three-phase unit with higher functions compare to the other REVEX 3PH models, because it is able to carry out phase angle firing with or without Current Limit. REVEX PA is therefore a unit suitable for driving inductive loads, such as three-phase transformers. The algorithms inside the unit allow the control of the power even for special loads, such as MoSi2 and SiC heating elements.

It is suitable for controlling both normal resistive loads and short, medium or long wave infrared lamps. Compared to the REVEX 3PH series, it has junctions with a high I2T suitable for managing the current peaks typical of IRSW (ultra short) lamps even on the smallest sizes such as 35A and 50A.

The unit can also be controlled through the analog input (4-20 mA / 0-10V) or via Modbus® serial communication.

The microprocessor allows different firing modes including Burst Firing, Phase Angle, Delayed Triggering, Zero Crossing.

The control can take place in Voltage, Current, Power or V2 and I2 with Transfer to VxI.

Another feature of our unit is the integrated USB port to configure the instrument in safe mode, without the aid of the connected load and auxiliary voltage. During setup, the unit is powered directly via USB.

Code / Size

REVEX PA – Order Code

Communication Module – Order Code


REVEX PA – Size and Dimensions

SW / Comm

USB device on front unit for configuration: Standard easily and safety normally used to configure the REVEX Eliminate the user having to work in a high voltage environment because the unit is powered through USB connection.

 

DOWNLOAD HERE THE FREE SOFTWARE TO CONFIGURE THE UNIT:


The configuration is done via a normal USB 2.0 cable – male A type to male Micro-B ( Order code if you buy it from us: USBMA-20-USBMMB ) and through a free configuration software that can be downloaded here:

ThyristorConfigurator V6.0.1.0

Thyristor configurator software
REVEX 1/2/3 PH - REVEX PA
REVO C 1/2/3 PH,
REVO PC v2
REVO PN v2
REVO PB
REVO RT
REVO TH

27.7 MiB

DOWNLOAD REVEX PROFINET Manual:

REVEX 14RX Profinet TU-RS485-PNTxRVXxx

Addendum: REVEX Profinet for 14 Thyristor units Code TU-RS485-PNTxRVXxx

0.7 MiB

 

DOWNLOAD REVEX PROFIBUS Manual:

REVEX 14RX Profibus TU-RS485-PDP_RVX14

Addendum: REVEX Profibus for 14 Thyristor units Code TU-RS485-PDP_RVX14

0.6 MiB

 

DOWNLOAD GSD Files:

PROFIBUS-GSD-Files

File GSD (General Station Description File) - Field bus PROFIBUS configuration file / File di configurazione del bus di campo PROFIBUS

11 KiB

PROFINET-GSDML-Files

File GSDML (General Station Description File) - Field bus PROFINET configuration file / File di configurazione del bus di campo PROFINET

85 KiB


Configurabilità del REVO ConnectFAST TUNE

The all new powerful Thyristor Configurator Software allows
you to configure all CD Automation products quickly and easily by using the FAST MODE. Simply select your application and the load type picture appears automatically, providing a list of suggested parameter settings. Depending on your application requirements, you can accept or make manual adjustments and when ready, download direct to the thyristor unit.



TEST UNIT
Configurabilità del REVO Connect

The TEST page is very useful when installing & commissioning
CD Automation products as well as finding process issues or fine tuning at a later stage. You can read, write, enable and disable key values and parameters to test your load. Examples include; reading voltage, current and power values, or current limit status, changing input types between analog or SSR, control (feedback) modes V, I and VxI, or select firing types half cycle, single cycle, burst firing, delayed triggering, phase angle and soft start. The new ‘Load Analyzer’ (a small oscilloscope) can be activated from this page, see below.



Analizzatore del Carico
LOAD ANALIZER

Provides real-time information of the output waveform, where
you can select up to 10 process variables to help the operator determine if the waveform is in line with process expectations. Also useful for trouble shooting.



Registrazione della Variabile di Processo del REVO ConnectPROCESS VARIABLE LOGGING

In REVO C Storage: 16GB SD Memory Card with programmable
Logging Intervals. Estimated storing 10 years. On other CD Automation Products the logging intervals are a fix value.

Documentation

REVEX PA – Documentation

Manuals

Serial Communication REVEX

Manual for Serial Communication

1.1 MiB

Catalog

 


3d Model

SR25

3D file for size SR25

32.6 MiB